NQM High Jitter Alarm

acNqmJitterAlarm

Alarm

acNqmJitterAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.90

Description

The alarm is sent when the device detects high jitter towards the Network Quality Monitoring (NQM) probe destination.

Default Severity

Minor

Alarm Source

Board#%d/NqmSender#%d

Event Type

CommunicationsAlarm

Probable Cause

The alarm is sent when high jitter is detected towards the NQM probe destination – thresholdCrossed.

Alarm Severity

Condition

Text

Corrective Action

Minor

-

Detected high Jitter towards NQM probe destination

To correct high jitter:

Test with traceroute.
Contact your Internet Service Provider (ISP) with traceroute results.
Implement Quality of Service (QoS).

Note: There's no simple solution for high jitter. A systemic level solution may be required.